GS 3060R2L Array (192.168.1.71)
System Information
Controller Time: 08/29/2023 13:34 PM
Configuration password: Yes
Maintenance password: Yes
Total Cache Size: 128GB (ECC DDR)
Firmware Version: 1.49C.14
BIOS Version 1.11H
Event Version: 20201127
Controller Position: Slot A
Service ID: 9146151
Slot A Serial Number: 9148031
Cache Backup Module: Cache Backup Module charging OFF (battery fully charged)
Cache Backup Module (Redundant): Cache Backup Module is disabled
ID of NVRAM Defaults: V2.85.300
Host Board - Slot A: FC 16G (SN: 9147236 (0x8B9364))
Host Board - Slot B: Host Board (SN: --)
I2C Device
Device Name: PSU0
Value:
Status: PSU0 functioning normally
I2C Device
Device Name: PSU1
Value:
Status: PSU1 functioning normally
I2C Device
Device Name: Cooling Fan0
Value:
Status: Cooling Fan0 is in lowest speed
I2C Device
Device Name: Cooling Fan1
Value:
Status: Cooling Fan1 is in lowest speed
I2C Device
Device Name: Cooling Fan2
Value:
Status: Cooling Fan2 is in lowest speed
I2C Device
Device Name: Cooling Fan3
Value:
Status: Cooling Fan3 is in lowest speed
I2C Device
Device Name: Backplane Temperature
Value: 41.0 C
Status: Temp. within safe range
Controller Device (Redundant)
Device Name: CPU Temperature (Redundant)
Value:
Status: Temp. sensor is NOT Present
Controller Device (Redundant)
Device Name: Controller Temperature(1) (Redundant)
Value:
Status: Temp. sensor is NOT Present
Controller Device (Redundant)
Device Name: Controller Temperature(2) (Redundant)
Value:
Status: Temp. sensor is NOT Present
Controller Device (Redundant)
Device Name: Controller Temperature(3) (Redundant)
Value:
Status: Temp. sensor is NOT Present
Controller Device (Redundant)
Device Name: +5V Value (Redundant)
Value:
Status: Voltage sensor is NOT Present
Controller Device (Redundant)
Device Name: +12V Value (Redundant)
Value:
Status: Voltage sensor is NOT Present
Controller Device (Redundant)
Device Name: Host Board (Redundant)
Value:
Status: Host Board is NOT Present
Controller Device
Device Name: CPU Temperature
Value: 50.0 C
Status: Temp. within safe range
Controller Device
Device Name: Controller Temperature(1)
Value: 46.5 C
Status: Temp. within safe range
Controller Device
Device Name: Controller Temperature(2)
Value:
Status: Hot Temp. Warning
Controller Device
Device Name: Controller Temperature(3)
Value: 61.5 C
Status: Temp. within safe range
Controller Device
Device Name: +5V Value
Value: 5.074 V
Status: Voltage within acceptable range
Controller Device
Device Name: +12V Value
Value: 12.094 V
Status: Voltage within acceptable range
Controller Device
Device Name: FC 16G
Value:
Status: FC 16G functioning normally
Controller Setting(s)
Controller Name: Not Set
Logo: GS 3060
Model: GS 3060R2L
Vendor: Infortrend
Raid Unique Identifier: 757543(0xB8F27)
Time Zone: -08:00
Date/Time: 2023-08-29 13:34
Access Mode: Out of Band
SNTP IP List (Polling Period: Not Set): Not Set
Drive Information
Logical Drive Setting(s)
Pool Information
Channel Setting(s)
Channel 0
Channel ID
MCS Group: 0
AID: 0
BID: 1
Channel Type: iSCSI
Channel Mode: Host
Data Service: Block-level Data Service
Current Data Rate:
Channel 1
Channel ID
MCS Group: 1
AID: 0
BID: 1
Channel Type: iSCSI
Channel Mode: Host
Data Service: Block-level Data Service
Current Data Rate:
Channel 2
Channel ID
MCS Group: 2
AID: 0
BID: 1
Channel Type: LAN
Channel Mode: Host
Data Service: File-level Data Service
Current Data Rate:
Channel 3
Channel ID
MCS Group: 3
AID: 0
BID: 1
Channel Type: LAN
Channel Mode: Host
Data Service: File-level Data Service
Current Data Rate:
Channel 4
Channel ID
AID: 112
Port Name:210400D0230B8F27, Node Name:200000D0230B8F27
BID: 113
Port Name:210400D0231B8F27, Node Name:200000D0231B8F27
Channel Type: Fibre
Channel Mode: Host
Data Service:
Current Data Rate:
Host Board
Slot A: FC 16G (SN: 9147236 (0x8B9364))
WWPN Port Name
Slot A
Slot B
Channel 5
Channel ID
AID: 112
Port Name:210500D0230B8F27, Node Name:200000D0230B8F27
BID: 113
Port Name:210500D0231B8F27, Node Name:200000D0231B8F27
Channel Type: Fibre
Channel Mode: Host
Data Service:
Current Data Rate:
Host Board
Slot A: FC 16G (SN: 9147236 (0x8B9364))
WWPN Port Name
Slot A
Slot B
Channel 6
Channel ID
AID: 112
Port Name:210600D0230B8F27, Node Name:200000D0230B8F27
BID: 113
Port Name:210600D0231B8F27, Node Name:200000D0231B8F27
Channel Type: Fibre
Channel Mode: Host
Data Service:
Current Data Rate:
Host Board
Slot A: FC 16G (SN: 9147236 (0x8B9364))
WWPN Port Name
Slot A
Slot B
Channel 7
Channel ID
AID: 112
Port Name:210700D0230B8F27, Node Name:200000D0230B8F27
BID: 113
Port Name:210700D0231B8F27, Node Name:200000D0231B8F27
Channel Type: Fibre
Channel Mode: Host
Data Service:
Current Data Rate: 16.0 Gbps
Host Board
Slot A: FC 16G (SN: 9147236 (0x8B9364))
WWPN Port Name
Slot A
Port Name:1000001086052D79, Node Name:2000001086052D79
Slot B
Channel 13
Channel Type: PCI-E
Channel Mode: RCCOM
Current Data Rate:
Host LUN List
Channel 0
SCSI ID 0
SCSI ID 1
Channel 1
SCSI ID 0
SCSI ID 1
Channel 2
SCSI ID 0
SCSI ID 1
Channel 3
SCSI ID 0
SCSI ID 1
WWN Name List
IQN List
Host-Side Parameters
Maximum Queued I/O Count: 1024
LUNs per Host SCSI ID: 32 LUNs
Login Authentication with CHAP: Disable
Jumbo Frames: Disable
Max Concurrent Host-LUN Connections: 4
Tags Reserved per Host-LUN Connection: 4
Peripheral Device Type: (TYPE = 0XD) Enclosure Services Device
Peripheral Device Qualifier: Connected
Device Supports Removable Media: Disable
LUN Applicability: First Undefined Lun
Cylinder/ Head/ Sector: Default(Variable/ Variable/ Variable)
Drive-Side Parameters
Disk Access Delay Time(Sec): No Delay
SAF-TE/SES Device Check Period(Sec): 30.0
Auto Rebuild on Drive Swap(Sec): 15.0
Disk I/O Timeout(Sec): 30.0
Auto-Assign Global Spare Drive: Disabled
SED Authentication Key: Not Set
SSD Remaining Life Notification: 12 %
Disk-Array Parameters
Rebuild Priority: Normal
Write Verify on LD Initialization: Disabled
Write Verify on LD Rebuild: Disabled
Write Verify on Normal Access: Disabled
Maximum Drive Response Timeout: Disabled
AV Optimization Mode: Disabled
Read-ahead Option for Media Editing: 0
Read-ahead Option for NAS File Transfer: 256k
Caching Parameters
Write-Back Cache: Enabled
Sync Period: Disabled
Communication
COM 1
Baud-rate: 38400
Terminal Emulation: Enabled
CH: 0
IP Assign Mode: DHCP
SlotA MAC Address: 00:D0:23:8B:8F:27
SlotB MAC Address:
SlotA IP Address:
SlotA Subnet Mask:
SlotA Default Gateway:
SlotB IP Address:
SlotB Subnet prefix length:
SlotB Default Gateway:
IPV6 Assign Mode: Disabled
SlotA IPV6 Address:
SlotA Subnet prefix length:
SlotA Default Gateway:
SlotB IPV6 Address:
SlotB Subnet prefix length:
SlotB Default Gateway:
CH: 1
IP Assign Mode: DHCP
SlotA MAC Address: 00:D0:23:4B:8F:27
SlotB MAC Address:
SlotA IP Address:
SlotA Subnet Mask:
SlotA Default Gateway:
SlotB IP Address:
SlotB Subnet prefix length:
SlotB Default Gateway:
IPV6 Assign Mode: Disabled
SlotA IPV6 Address:
SlotA Subnet prefix length:
SlotA Default Gateway:
SlotB IPV6 Address:
SlotB Subnet prefix length:
SlotB Default Gateway:
CH: 2
IP Assign Mode: DHCP
SlotA MAC Address: 00:d0:23:c9:8f:27
SlotB MAC Address: 00:d0:23:d9:8f:27
SlotA IP Address:
SlotA Subnet Mask:
SlotA Default Gateway:
SlotB IP Address:
SlotB Subnet prefix length:
SlotB Default Gateway:
IPV6 Assign Mode: Disabled
SlotA IPV6 Address:
SlotA Subnet prefix length:
SlotA Default Gateway:
SlotB IPV6 Address:
SlotB Subnet prefix length:
SlotB Default Gateway:
CH: 3
IP Assign Mode: DHCP
SlotA MAC Address: 00:d0:23:29:8f:27
SlotB MAC Address: 00:d0:23:39:8f:27
SlotA IP Address:
SlotA Subnet Mask:
SlotA Default Gateway:
SlotB IP Address:
SlotB Subnet prefix length:
SlotB Default Gateway:
IPV6 Assign Mode: Disabled
SlotA IPV6 Address:
SlotA Subnet prefix length:
SlotA Default Gateway:
SlotB IPV6 Address:
SlotB Subnet prefix length:
SlotB Default Gateway:
LAN: 0
IP Assign Mode: Static
MAC Address: 00:d0:23:09:8f:27
IP Address: 192.168.1.71
Subnet Mask: 255.255.255.0
Default Gateway:
IPV6 Assign Mode: Disabled
IPV6 Address:
Subnet prefix length:
Default Gateway:
Net Protocols
All: Enabled
Telnet: Disabled
HTTP: Disabled
HTTPS: Disabled
FTP: Disabled
SSH: Disabled
Out-of-band agent : Enabled
Out-of-band agent (SSL): Enabled
SNMP: Enabled
DHCP: Enabled
PING: Enabled
Discovery: Enabled
Trigger
Controller Failure: Disable
CBM Lower or Failure: Enable
Power Supply Failed: Disable
Fan Failure: Disable
Temperature exceeds threshold: Disable
Threshold
CPU Temperature: 50.0 C
Lower Bound: 0.0 C
Upper Bound: 88.0 C
Controller Temperature: 46.5 C
Lower Bound: 0.0 C
Upper Bound: 90.0 C
+5V Value: 5.079 V
Lower Bound: 4.5 V
Upper Bound: 5.5 V
+12V Value: 12.107 V
Lower Bound: 10.8 V
Upper Bound: 13.2 V
Redundant
Redundant Configuration: Scanning
Shutdown Configuration
Shutdown Status: No pending or previously issued shutdown command
(In Raid) Task List
Pair List
Remote Media Extent List
License Information List
License Type: Thin provisioning
Due To Expire: No due day
License Type: Snapshot
Image Amount (Partition/Subsystem): 64/128
Due To Expire: No due day
License Type: Volume Copy
Pair Amount (Partition/Subsystem): 4/16
Due To Expire: No due day
License Type: Volume Mirror
Pair Amount (Partition/Subsystem): 4/16
Due To Expire: No due day
License Type: Maximum Number of Expansion Enclosure per Chain
Max JBOD Size: 15
Due To Expire: No due day
License Type: Self-Encryption Drives
Due To Expire: N/A
License Type: EonCloud Gateway
Version: Standard